AGENDA :Introduction1.Energy Efficiency for HVAC2.Energy Efficiency for Lightings3.Energy Efficiency for Lifts and Escalators4.Energy Efficiency for other Equip/Materials1
SpaceConditioning48%OfficeEquipment22%Other (e.g.Lifts)11%Lighting19%Rough proportion of electricity consumption in acommercial buildingIntroduction2
Energy Efficency Considerationsin BS design :Electronic ballast for luminairesT5 fluorescent luminaires and LED…Photo-sensor control for lightingOccupancy sensor to control lighting & A/C on/offCO2sensor control to limit over-provide of pre-treatedfresh air supplyWater cooled chiller plantsHeat Pump systemsFree cooling for offices in winterBleed-off / Grey water for toilet flushingIntroduction(Cont’d)3
1.HVAC Equipment & Systems®Most 3-phase induction motors for chillers orpumpsshallbe driven viavariable-speed drive(VSD)seed-drive(VSD) fans®Air or water flow is either constant volume orregulated by mechanical means, e.g. airvanes/dampers, water by-pass valve, etc.®Mechanical volume control adds loss in the systemand is energy inefficient.®As power required by fan or pump reducedproportionally to the cube power of the motorspeed (Fan Laws), the application of VSD in volumeflow control is more energy efficient, e.g. 20%speed reduction in motor need 51% of the originalpower.4
Motor Energy Saving with VSD020406080100120020406080100120Speed/Flow %Motor Power %Fan/Pump Cube LawHVAC Equipment & Systems(cont’d)5
®Fresh air (FA) supply in building is normally fed via PAU atconstant air volume based on FA at 10 litres/s /person (seeASHRAE 62.2000)®PAU then pre-treats & coolsthe outdoor air from thedesignedoutdoor temperature of33.5oC to a lower value®Constant FA is a great wastage of energy®Demand control on PAU using CO2sensor & VSD motors cansave energy in the air-conditioned space with variable andintermittent occupancy, such as vacant at lunch time …®CO2content of <1000 ppm is required according to ASHRAEstandardandthe HK IAQGuidance NotesEnergy Efficient HVAC Equipment & Systems(Cont’d)6
Queensway Gov’tOffices - VSD for 3 nos. 37 kWchilled water pumpsExamples on Buildings using VSD for pumps…7
Examples ofusingVSDinChillersShatin Town Hall – 400 TR water-cooled chillerretrofitted with VSD to improve its part-loadperformance8
lEvaporating cooling for air-cooled chillers atTsuen Wan Yeung Uk Road Indoor GamesHall (increased of energy saving by 15% )Another example on using external waterspraying system to improve the COP ofchiller9
l

Upload your study docs or become a

Course Hero member to access this document

Upload your study docs or become a

Course Hero member to access this document

End of preview. Want to read all 47 pages?

Upload your study docs or become a

Course Hero member to access this document

Term
Fall
Professor
N/A
Tags
Incandescent light bulb, Fluorescent lamp, Electrical ballast

Newly uploaded documents

Show More

Newly uploaded documents

Show More

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture