Dr. Emmert POSC 1023 16 November 2006 Problem Set 3B 1. Summer ventilation is mainly used to remove heat and moisture from the house, and often a negative pressure tunnel system is used. Fans are used to pull air through the house and cool the birds, while also using evaporative cooling pads. Winter ventilation can be a little more complicated because of the removal of moisture and ammonia removal. A negative pressure system is used to remove moisture without chilling the birds too much. The cool air mixes with the warm air before coming in contact with the birds. 2. Negative pressure systems are usually preferred to positive pressure systems because of the uniformity of air flow. The advantages of a negative pressure system include allowing the air to stay very close to the ceiling as it moves down the center aisle and warming the air before it comes in contact with the birds. The system works by using
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Background image of page 2
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: sidewall exhaust fans with adjustable sidewall air inlets. The system brings air in on the high side walls and shoots the cold outside air into the middle of the house. 3A. (.95)(4.5)(30,000) = 128,000 128,000/10,000 = 12.8 13 Fans 3B. (20BTU)(30,000) = 600,000 600,000 – 120,000 = 480,000 BTU’s/hr 4A. MAX—(600)(45)(10) = 270,000 270,000/10,000 = 27 Fans MIN—(350)(45)(10) = 157,500 157,500/10,000 = 16 Fans 4B. MIN= NO, MAX=YES 5. (18)(10,000) = 180,000 (L)(45)(10) = 180,000 L = 400 ft/min 6A. (6)(24) = 144 (144)/(12) = 12 (12)(50) = 600 ft/min 6B. (2)(10,000) = 20,000 (20,000)/(600) = 33.33 ft/min –OPEN (2)(10,000) = 20,000 (20,000)/ 300 = 66.6667ft/min –HALF 6C. (20,000)/(625) = 32 square feet 6D. .42/1000 = 20,000/1 min = 8.4 lb/min (8.4)(60) = 504 lb/hour 504/I hour = x/8.2 = 62 gallons (20,000)(.021)(24) = 10,080 10,080/1 day = 1/ 504 = 20 hours...
View Full Document

This note was uploaded on 04/26/2008 for the course POSC 1023 taught by Professor Emmert during the Fall '06 term at Arkansas.

Page1 / 2

problem set 3B - sidewall exhaust fans with adjustable...

This preview shows document pages 1 - 2. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online