ASTM C1437 - F low of H yd raulic Cement Mo r ta r ASTM...

Info iconThis preview shows pages 1–2. Sign up to view the full content.

View Full Document Right Arrow Icon

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: F low of H yd raulic Cement Mo r ta r ASTM C-1437 Tim Boyer CM 442 P re-L ab Pu rpose The purpose of this lab is to provide a standardized method for determining the f low of hydraulic cement mortars. Equipment Flow Table, Flow Mold Caliper Tamper Trowel Straightedge P rocedure Place f low mold on clean dry table Place a layer of mortar about 1 in thick in mold and tamp 20 times with tamper Then fill the mold with mortar and tamp Cut off mortar to a plane surface f lush with top of the mold Lif t mold away after 1 min Immediately drop the table through a height of 0.5 in 25 t imes in 15s Measure resulting diameter and express as a percent of original diameter Post-L ab Test Conditions The test conditions for this procedure were normal. Results N-S E-W NWSE NESW avg Flow= 10.9 10.8 10.5 10.6 10.7 167.5 Comments The procedure was followed as wri t ten and everything proceeded normally. ...
View Full Document

This note was uploaded on 04/29/2008 for the course CE 320 taught by Professor Mckinney during the Spring '08 term at Rose-Hulman.