source: Uniform Building Code (1997). IBCO. TABLE 16-A UNIFORM AND CONCENTRATED LOADS USE OR OCCUPANCY UNIFORM LOAD 1 (psf) CONCENTRATED LOAD (Pounds) Category Description x 0.0479 for kN/m2 x 0.004 48 for kN 1. Access floor systems Office use 50 2000 Computer use 100 2000 2. Armories 150 3. Assembly areas 3 and auditoriums and balconies therewith Fixed seating areas 50 0 Movable seating and other areas 100 0 Stage areas and enclosed platforms 125 0 4. Cornices and marquees 60 0 5. Exit facilities 5 100 0 6 6. Garages General storage and/or repair 100 [ ] 7 Private or pleasure-type motor vehicle storage 50 [ ] 7 7. Hospitals Wards and rooms 40 1,000 2 8. Libraries Reading rooms 60 1,000 2 Stack rooms 125 1,500 2 9. Manufacturing Light 75 2,000 2 Heavy 125 3,000 2 10. Offices 50 2,000 2 11. Printing plants Press rooms 150 2,500 2 Composing and linotype rooms 100 2,000 2 12. Residential 8 Basic floor area 40 0 6 Exterior balconies 60 4 0 Decks 40 4 0 Storage 40 0 13. Restrooms 9 100 0 14. Reviewing stands, grandstands, bleachers, and folding and telescoping seating 100 0