EE 341 – ENERGY CONVERSION 1 1. Problem 5-3 on textbook (Chapman, page 318) A 480-V, 200-kVA, 0.8-PF-lagging, 60-Hz, two-pole, Y-connected synchronous generator has a synchronous reactance of 0.25 and an armature resistance of 0.04 . At 60 Hz, its friction and windage losses are 6kW, and its core losses are 4kW. Assume that the field current of the generator has been adjusted to a value of 4.5 A ( so that the open-circuit terminal voltage of the generator will be about 477 V ). (a) What will the terminal voltage of this generator be if it is connected to a - connected load with an impedance of 5/30 o ? (b) Sketch the phasor diagram of this generator. (c) What is the efficiency of the generator at these conditions? (d) Now assume that another identical -connected load is to be paralleled with the first one. What happens to the phasor diagram for the generator? (e) What is the new terminal voltage after the load has been added?
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Background image of page 2
Background image of page 3

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Background image of page 4
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: (f) What must be done to restore the terminal voltage to its original value? EE 341 ENERGY CONVERSION 2 EE 341 ENERGY CONVERSION 3 2. Problem 5-7 on textbook (Chapman, page 319) A 13.5-kV, 20-MVA, 0.8-PF-lagging, 60-Hz, two-pole, Y-connected steam-turbine generator has a synchronous reactance of 5.0 per phase and an armature resistance of 0.5 per phase. This generator is operating in parallel with a large power system (infinite bus). (a) What is the magnitude of E A at rated conditions? (b) What is the torque angle of the generator at rated conditions? (c) If the field current is constant, what is the maximum power possible out of this generator? (d) At the absolute maximum power possible, how much reactive power will this generator be supplying or consuming? Sketch the corresponding phasor diagram. (Assume I F is still unchanged.) EE 341 ENERGY CONVERSION 4...
View Full Document

This note was uploaded on 05/01/2008 for the course ECE 341 taught by Professor Keyhani during the Spring '08 term at Ohio State.

Page1 / 4

hw6s - (f) What must be done to restore the terminal...

This preview shows document pages 1 - 4. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online