ABSTRACT: In this experiment the aim was to investigate column chromatography and factors  affecting it. Three different columns  were prepared with different adsorbents or solvent  addition order and the same dye was separated into its components. The first column has  separated into blue and yellow successfully. The cup containing blue dye and ethanol has  65.2% yield, the cup containing yellow dye and water has 68% yields. The second column  separation could not be held successfully. Yield could not be calculated. In the last column  only yellow dye could be removed from the column. Blue dye left in between the adsorbent.  The percent yield of the yellow dye obtained from column 3 is 81.6%. INTRODUCTION: The aim of this experiment was to apply the last type of separation technique  of this course: column chromatography. To be able to understand the technique  factors affecting the quality of separation is also investigated in depth. In column chromatography the material to be separated is placed into a  vertical column which has adsorbent in it. Mainly there are two phases exist:  stationary and mobile. Stationary phase is a solid where mobile phase is a liquid  solvent. [1]. As the material is dissolved in the solvent and passed through the  adsorbent with the help of the gravity or vacuum, the components can be collected.  Column chromatography is used for analysis or purification. It is divided into  two types: gravity column chromatography or flash chromatography. In this experiment  gravity column chromatography was applied. But, if a pressure is applied to the material in  the column, this becomes flash chromatography which was named by Professor W. Clark  Still. [1]. The crucial factors in column chromatography can be listed as below: 1- Effect of the Adsorbent: 2- Effect of the Solvent 3- Effect of Packaging Generally silica gel (SiO 2 ) or alumina (Al 2 O 3 )is preferred as adsorbents. The size of the  particle determines the flow rate also permits the components having adequate size to pass  through the adsorbent.    1
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
The polarity of the solvent is important in separation due to “likes dissolve likes” principle.  The components could not flow through the column unless it is dissolved in the solvent. And packaging has a similar role like adsorbent choice, because how tight the adsorbent 
Background image of page 2
Image of page 3
This is the end of the preview. Sign up to access the rest of the document.

This note was uploaded on 04/17/2009 for the course CHEM chem206 taught by Professor F.y during the Spring '09 term at Kalamazoo Valley Community College.

Page1 / 7

chem206 Rapor-9 - ABSTRACT: In this experiment the aim was...

This preview shows document pages 1 - 3. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online