HW22 - C and a condenser pressure of 1.2 MPa. For a...

Info iconThis preview shows page 1. Sign up to view the full content.

View Full Document Right Arrow Icon
Spring 2006 1 ME 201 Thermodynamics Homework 22, Due Friday, May 5, 2006 Extra Credit worth 15 points 1. An ideal vapor –compression refrigeration cycle with refrigerant 134a as the working fluid operates with an evaporator temperature of –20
Background image of page 1
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: C and a condenser pressure of 1.2 MPa. For a refrigerant flow rate of 3 kg/min determine: a. COP for the cycle b. Cooling load in kW for the cycle c. Carnot cycle COP for the given conditions...