Unit V Assessment.docx - Course Test Started Submitted Status Attempt Score Time Elapsed Instructions BOS4025-16G-4 OSHA Standards Unit V Assessment

Unit V Assessment.docx - Course Test Started Submitted...

This preview shows page 1 - 4 out of 9 pages.

Course BOS4025-16G-4, OSHA Standards Test Unit V Assessment Started 3/5/19 5:35 PM Submitted 3/9/19 3:04 PM Status Completed Attempt Score 75 out of 100 points Time Elapsed 93 hours, 29 minutes Instructions Assessment Instructions Results Displayed Submitted Answers, Correct Answers, Feedback Question 1 5 out of 5 points Which of the following types of vehicles is not covered by 29 CFR 1910.178, Powered Industrial Trucks? Selected Answer: Earth-moving vehicles Correct Answer: Earth-moving vehicles Question 2 5 out of 5 points What is the correct definition of dry powder? Selected Answer: A compound used to extinguish or control Class D fires Correct Answer: A compound used to extinguish or control Class D fires Question 3 5 out of 5 points Workplaces using electrically powered industrial trucks will have battery charging areas somewhere in the plant. Which of the following is NOT a requirement in the standard? Selected Answer: Placing charging stations outdoors in a covered area
Image of page 1
Correct Answer: Placing charging stations outdoors in a covered area Question 4 5 out of 5 points In an overhead crane, what must be displayed on either side of the crane so as to be visible from the ground? Selected Answer: The crane's rated load Correct Answer: The crane's rated load Question 5 5 out of 5 points All wiring and equipment on overhead or gantry cranes shall comply with the applicable electrical sections of __________. Selected Answer: Subpart S Correct Answer: Subpart S Question 6 5 out of 5 points List three conditions that, if found in a wire rope sling, would require the sling to be removed from service immediately. Include the citation for the OSHA standard where you found the answer to the question. Your response should be at least 75 words in length. Selected Answer: According to 1910.184(f)(5) wire rope slings should be removed from service immediately if they meet 7 conditions. Three of the seven conditions are: if the end attachments are worn, cracked, or deformed, rope attachments are corroded, if the hooks have been open more than 15 percent, or there has been evidence of
Image of page 2
heat damage. Correct Answer: [None] Response Feedback: Antonio, Here is the grading according to the rubric: Content, 2/2; Organization: 2/2, Writing Mechanics: 1/1; Total: 5/5 The abundance of wire rope on the job site allows for a very large number of issues when conducting lifts. With so many opportunities for failure we need to be sure our riggers are very capable of identifying the necessary hazards.
Image of page 3
Image of page 4

You've reached the end of your free preview.

Want to read all 9 pages?

  • Fall '15
  • Internal combustion engine, Fire extinguisher

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture

Stuck? We have tutors online 24/7 who can help you get unstuck.
A+ icon
Ask Expert Tutors You can ask You can ask You can ask (will expire )
Answers in as fast as 15 minutes