Spring 2018 Spring Term Project Hospital Building Design Submitted to: Submitted By: Name: Student ID:
Image of page 1
TABLE OF CONTENTS Introduction ................................................................................................................................................. 4 Abstract ....................................................................................................................................................... 4 Procedure ..................................................................................................................................................... 4 Load calculations ......................................................................................................................................... 4 Live load .................................................................................................................................................. 5 Dead load ................................................................................................................................................. 5 Wind load ................................................................................................................................................ 6 West-East wind ........................................................................................................................................ 7 Windward ........................................................................................................................................ 7 The windward wall pressure coefficient is cp = 0.8. The values for the increasing height are shown in Table 2 below. .......................................................................................................................................... 7 Sidewall ................................................................................................................................................... 9 Roof load ............................................................................................................................................... 10 Figure 1: Top view of the Hospital .................................................................................................... 11 Figure 2: Geometrical STAAD design ............................................................................................... 12 Conclusion ................................................................................................................................................. 12 2
Image of page 2
LIST OF TABLE AND FIGURES List of Tables Table 1.Exposure coefficient ....................................................................................................................... 6 Table 2. Windward pressure for case 1 ........................................................................................................ 7 Table 3. Leeward pressure for case 1 ........................................................................................................... 9 Table 4. Sidewalls pressure for case 1 ......................................................................................................... 9 Table 5. Roof pressure for case 1 ............................................................................................................... 10 Table 6. Roof load ..................................................................................................................................... 10 List of Figures Figure 1. Load distribution ...................................................................................................................... 11 Figure 2.STAAD geometery image ........................................................................................................... 12 3
Image of page 3
Introduction A four-storey hospital structure with 96x60 dimensions is to be erected at Jonesboro; AR. Structure’s plan view is displayed below. The height for the first and second floor stands at 14ft and 12ft, respectively. Both the roof and floors are 6 inches and 7inches thick in that order. The measurement of the girders is 40x20 inches, all created from reinforced concrete. The patients are housed in first and second floors whereas the operating rooms and laboratories are accommodated on the third floor. The roof’s snow load is 10psf. The ceilings are made from gypsum plaster and metal lath. The waterproofing membrane is applied in roof cover while ceramic tiles (0.5 inches) are used for the finishing of the floor. The building’s walls are
Image of page 4
Image of page 5

You've reached the end of your free preview.

Want to read all 13 pages?

  • Summer '18
  • Indrajit
  • Inch, Dead and live loads, ASCE

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture

Stuck? We have tutors online 24/7 who can help you get unstuck.
A+ icon
Ask Expert Tutors You can ask You can ask You can ask (will expire )
Answers in as fast as 15 minutes