Roads and gutters are already
filled of
No Gate and Guard House to
control entry and exit points of
vehicle even passerby and people
entering the hospital
The Signage for the entrance is
not very visible for those who
don’t know the place
Cavite Health
Collaboration
Center
Power supply – Meralco and
Genset area needs to be retrofit
the building and housing
No proper signage or labeling as
to Caution High Voltage or
Power Supply Station
Existing drainage systems and
open canal are not properly
cover and exposed to insects
and other mosquito
Parking Area including the Rotanda is not organize on the
parking of the vehicle.
Old Linen
storage that
has no use
now
Other view of the Main Building
Maintenance
Engineering Facilities
department of the
hospital is very poor

Subscribe to view the full document.
Laundry area is very poor as to
proper lighting, water supply
and hanging of wet bed sheets
and pillows.
Access from the lef
side of the hospital
going to the dumping
site of garbage needs
to provide concrete
pedestrian
Nursing Services
GEAMH Eco Center
Pedia Ward
Hospital Morge but is not used
because the dead patients just
let it lie down there and take
them to the near funeral parlor
Municipal
Hospital
Medical Ward
Surgical Ward

GEAMH Site Development Plan
Patient
Department
Emergency rooms
Waiting area for
patients

Subscribe to view the full document.
Site Evaluation Rating Scale by Proponent
Rating Scale
Site Characteristics
Remarks
5.0
0
Excellent, Highly
Preferable
The site conforms to the site evaluation
standard, providing a perfect project
conformance to the standard
Strength/Opportunity
4.0
0
Very Satisfactory,
Preferable
The site conforms to the site evaluation
standard, providing a perfect project
conformance to the standard
Strength/Opportunity
3.0
0
Fair,
Disadvantageous
The site does not exactly conform o the
standard, but external proposals or action can
be made in order to attain conformance. If not
acted upon site condition may post
disadvantage
Weakness/Threats
2.0
0
Conditional, Very
Disadvantageous
The site does not exactly conform to the
standard however no solution can be made to
solve the problem, thus creating a natural
threat to the site, resiliency becomes a must
Weakness/Threats
1.0
0
Poor, extremely
Disadvantageous
The site does not follow the standards of the
rule and the site can be very dangerous, threat
maybe life threatening.
Weakness/Threats
Summary of Site Evaluation
Site Evaluation
Criteria
Criteria Definition
Analysis on Site
Rating
Remarks
Major Criteria
General
Location
Geographical
Centrality
The local government code of the
Philippines 1991 included