M. Thust et al., Analytica Chimica Acta 323 (1996) 115-121 Penicillin Sensor Penicillin Sensor The enzyme penicillinase hydrolyzes penicillin dissolved in aqueous solution to liberate a hydrogen ion: penicillin + H 2 0 => penicilloate - + H +
Background image of page 2
Penicillin Sensor Penicillin Sensor Change in pH Change in surface charge Change in zeta-potential Shift in capacitance- voltage curves Adjust the voltage to keep the capacitance constant M. Thust et al., Analytica Chimica Acta 323 (1996) 115-121
Background image of page 3

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full Document Right Arrow Icon
Penicillin Sensor – Long-term Stability Penicillin Sensor – Long-term Stability M. Thust et al., Analytica Chimica Acta 323 (1996) 115-121
Background image of page 4
Background image of page 5

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full Document Right Arrow Icon
Background image of page 6
Background image of page 7

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full Document Right Arrow Icon
Background image of page 8
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: M. Schoening et al., Sensors and Actuators B 47 (1998) 225–230 Penicillin Sensor – pH Reference Penicillin Sensor – pH Reference M. Schoening et al., Sensors and Actuators B 47 (1998) 225–230 Penicillin Sensor – pH Reference Penicillin Sensor – pH Reference M. Schoening et al., Sensors and Actuators B 47 (1998) 225–230 Penicillin Sensor – pH Reference Penicillin Sensor – pH Reference S. Caras and J. Janata, Anal. Chem. 52, 1935-1937 (1980) Penicillin Sensor – ISFET design Penicillin Sensor – ISFET design • Different immobilization: Lifetime only 60 days !...
View Full Document

{[ snackBarMessage ]}

Page1 / 8

Penicillin_sensor - M Schoening et al Sensors and Actuators...

This preview shows document pages 1 - 8. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online