Lab 6 - Analysis of a Heat Exchanger

Lab 6 - Analysis of a Heat Exchanger - Analysis of an Air...

Info iconThis preview shows pages 1–4. Sign up to view the full content.

View Full Document Right Arrow Icon
Analysis of an Air Conditioning System A report on an experiment performed for ME 115 Thermal Engineering Laboratory San Jose State University Department of Mechanical and Aerospace Engineering By
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Table of Contents Abstract ---------------------------------------------------------------------------------3 Introduction ---------------------------------------------------------------------------------4 Theory ---------------------------------------------------------------------------------5 Experimental Setup and Procedure ------------------------------------------------------6 Experimental Results and Calculations ---------------------------------------------7 Discussion of Results ------------------------------------------------------------------------11 Conclusion and Recommendations ------------------------------------------------------12 References ---------------------------------------------------------------------------------13 Appendices Appendix A: Raw Data ----------------------------------------------------------------------14 Appendix B: Properties of Refrigerant 12 ------------------------------------------------15 Appendix C: Psychrometric Chart----------------------------------------------------------18
Background image of page 2
Abstract An heat exchanging process which consists of umixed cross-flowing of the enviroment's air with a recirculated hot water was analyzed using a heat exchanger laboratory unit which uses purified water. This experiment demonstrates the heat and energy transfers of both fluids, which consists of filtered air entering the ducting and going through a VAV damper , the heat exchanger and then passing the pressure sensors at the outlet where the fan that is driving the whole process is further down the ductings. Measurements of temperatures were taken at inlet, outlet of the process as well as the inlet and outlet of
Background image of page 3

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Image of page 4
This is the end of the preview. Sign up to access the rest of the document.

Page1 / 9

Lab 6 - Analysis of a Heat Exchanger - Analysis of an Air...

This preview shows document pages 1 - 4. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online