70072-0154-03 TECHNICAL NOTE 08/2008 ION, ION Enterprise, Power Measurement, PowerLogic, and Schneider Electric are either trademarks or registered trademarks of Schneider Electric in France, the USA and other countries. All other trademarks are property of their respective owners. Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. © 2008 Schneider Electric. All rights reserved. www.powerlogic.com ION8600 Sag/Swell Module The PowerLogic™ ION8600 Sag/Swell module monitors voltage inputs for disturbances, which are defined as one or more of the inputs straying above a high limit (swells) or below a low limit (sags or interruptions). When it detects a disturbance, the Sag/Swell module provides information about the entire disturbance; in addition, it breaks up the disturbance into discrete components, or sub disturbances , to provide for a more detailed analysis. N OTE The modifications described in this document are specific to the ION8600 meter. In this document ± Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Sag/Swell Module in the ION8600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Method of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 If there is a power outage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ± Sag/Swell Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Sag/Swell Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Sag/Swell Module Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ± Detailed Module Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Power Tolerance Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Disturbance Categories as Defined by IEEE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Disturbance Sub Divisions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Responses to Special Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full Document Right Arrow Icon
Introduction ION8600 Sag/Swell Module Page 2 © 2008 Schneider Electric. All rights reserved. Introduction The primary application for the Sag/Swell module is voltage quality monitoring and analysis. The module monitors voltage inputs for disturbances, which are defined as one or more of the inputs straying above a high limit (swells) or below a low limit (sags or interruptions). When it detects a disturbance, the Sag/Swell module provides information about the entire disturbance; in addition, it breaks up the disturbance into discrete components, or sub disturbances , to provide for a more detailed analysis. Sag/Swell Module in the ION8600 The Sag/Swell module in the ION8600 meter has been modified to operate a blade powered meter in a similar manner as an auxiliary powered meter. It now records outage duration and voltage level when the blade powered meter turns off (i.e. a true 3 phase outage). Typically, an auxiliary powered meter records all outages as sags because the meter is still powered up when the supply voltage goes down. An outage on a blade powered meter will cause the Sag/Swell module to respond in a similar manner. N OTE The modifications described below are for the ION8600 meter only. Method of Operation The outage duration is calculated upon start up and is registered in the DistDur output register. Outage duration is calculated as the time between the start of the sag (just before the outage) and when the meter powered up again. The startup time is considered a fixed constant when calculating the outage time. The
Background image of page 2
Image of page 3
This is the end of the preview. Sign up to access the rest of the document.

{[ snackBarMessage ]}

Page1 / 9

8600_Sag_Swell_Module - TECHNICAL NOTE 70072-0154-03...

This preview shows document pages 1 - 3. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online