Abstract: In this lab, the chemical components of Excedrin and Tylenol, two common, over-the-counter analgesic drugs, were determined by utilizing the technique of thin-layer chromatography, or TLC. The active ingredients of Excedrin were caffeine, acetaminophen, and aspirin with R f values of 0.11, 0.38, and 0.61, respectively. The lone active ingredient of Tylenol was acetaminophen with an R f value of 0.39. The elution sequence obtained in the experiment is as follows: ibuprofen (least polar), acetylsalicylic acid, acetaminophen, and caffeine (most polar). Purpose of Experiment: The objective of this experiment is to determine the active ingredients contained within a series of over-the-counter painkillers using thin-layer chromatography or TLC. Introduction and Background: TLC is a quick and convenient chromatographic method for analyzing a mixture by separating its constituent compounds. Along with determining the number of components in a mixture, TLC can also be
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
of aid in identifying unknown compounds. Separation of compounds is achieved as a partitioning occurs between a mobile phase and a stationary phase. In TLC, the stationary phase is composed of a thin layer of the highly polar silica gel that is deposited on a glass or plastic plate, and the mobile phase consists of a liquid solvent that runs up the plate through capillary action, carrying the solutes, or the chemical compounds that are to be separated and analyzed. The principles of polarity and of intermolecular attractions are of importance in determining how compounds will behave during the separation. While the more polar components of a mixture will stick more strongly to the polar stationary phase and thus, move slower, the least polar components will move the fastest and run higher up the plate. Once separation is achieved, the compounds are then identified by the position of a spot on the plate after development, which enables one to determine the retardation factor, or R f value, for each compound in the solvent system used. The R f value is calculated using the following equation: R f = distance traveled by substancedistance traveled by solvent front In this experiment, by first developing a plate with the knowns, or standards of analgesic
Background image of page 2
Image of page 3
This is the end of the preview. Sign up to access the rest of the document.

This note was uploaded on 11/03/2010 for the course CHEM 243 A taught by Professor Koerner during the Fall '10 term at University of Arizona- Tucson.

Page1 / 7

tlc - Abstract: In this lab, the chemical components of...

This preview shows document pages 1 - 3. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online