Abstract: In this lab, the chemical components of Excedrin and Tylenol, two common, over-the-counter analgesic drugs, were determined by utilizing the technique of thin-layer chromatography, or TLC. The active ingredients of Excedrin were caffeine, acetaminophen, and aspirin with R f values of 0.11, 0.38, and 0.61, respectively. The lone active ingredient of Tylenol was acetaminophen with an R f value of 0.39. The elution sequence obtained in the experiment is as follows: ibuprofen (least polar), acetylsalicylic acid, acetaminophen, and caffeine (most polar). Purpose of Experiment: The objective of this experiment is to determine the active ingredients contained within a series of over-the-counter painkillers using thin-layer chromatography or TLC. Introduction and Background: TLC is a quick and convenient chromatographic method for analyzing a mixture by separating its constituent compounds. Along with determining the number of components in a mixture, TLC can also be
Image of page 1

Info icon This preview has intentionally blurred sections. Sign up to view the full version.

View Full Document Right Arrow Icon
of aid in identifying unknown compounds. Separation of compounds is achieved as a partitioning occurs between a mobile phase and a stationary phase. In TLC, the stationary phase is composed of a thin layer of the highly polar silica gel that is deposited on a glass or plastic plate, and the mobile phase consists of a liquid solvent that runs up the plate through capillary action, carrying the solutes, or the chemical compounds that are to be separated and analyzed. The principles of polarity and of intermolecular attractions are of importance in determining how compounds will behave during the separation. While the more polar components of a mixture will stick more strongly to the polar stationary phase and thus, move slower, the least polar components will move the fastest and run higher up the plate. Once separation is achieved, the compounds are then identified by the position of a spot on the plate after development, which enables one to determine the retardation factor, or R f value, for each compound in the solvent system used. The R f value is calculated using the following equation: R f = distance traveled by substancedistance traveled by solvent front
Image of page 2
Image of page 3
This is the end of the preview. Sign up to access the rest of the document.

{[ snackBarMessage ]}

What students are saying

  • Left Quote Icon

    As a current student on this bumpy collegiate pathway, I stumbled upon Course Hero, where I can find study resources for nearly all my courses, get online help from tutors 24/7, and even share my old projects, papers, and lecture notes with other students.

    Student Picture

    Kiran Temple University Fox School of Business ‘17, Course Hero Intern

  • Left Quote Icon

    I cannot even describe how much Course Hero helped me this summer. It’s truly become something I can always rely on and help me. In the end, I was not only able to survive summer classes, but I was able to thrive thanks to Course Hero.

    Student Picture

    Dana University of Pennsylvania ‘17, Course Hero Intern

  • Left Quote Icon

    The ability to access any university’s resources through Course Hero proved invaluable in my case. I was behind on Tulane coursework and actually used UCLA’s materials to help me move forward and get everything together on time.

    Student Picture

    Jill Tulane University ‘16, Course Hero Intern