1230 vm102 analysis assumptions and modeling notes

Info iconThis preview shows page 1. Sign up to view the full content.

View Full Document Right Arrow Icon
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: in of unit depth (Z-direction). POST1 is used to obtain results from the solution phase. Results Comparison Target[1] ANSYS Ratio T, °F (at Node 1) 93.7 93.6 1.00 T, °F (at Node 2) 56.3 56.8 1.01 T, °F (at Node 3) 22.2 22.1 0.99 T, °F (at Node 4) 93.2 93.2 1.00 T, °F (at Node 5) 54.6 54.9 1.01 T, °F (at Node 6) 21.4 21.1 0.98 T, °F (at Node 7) 87.6 87.8 1.00 T, °F (at Node 8) 47.5 47.7 1.01 T, °F (at Node 9) 18.3 17.3 0.95 T, °F (at Node 11) 29.6 27.6 0.93 T, °F (at Node 12) 11.7 12.5 1.07 T, °F (at Node 15) 4.7 5.0 1.07 q, Btu/hr 775.2 773.5[2] 1.00 1. Based on a numerical relaxation method. 2. From heat rates at elements 1 and 3 multiplied by 8. 1–226 ANSYS Verification Manual . ANSYS Release 9.0 . 002114 . © SAS IP, Inc. VM100 Figure 100.2 Temperature Contour Display ANSYS Verification Manual . ANSYS Release 9.0 . 002114 . © SAS IP, Inc. 1–227 VM101: Temperature Distribution in a Short Solid Cylinder Overview Reference: P. J. Schneider, Conduction Heat Transfer, 2nd P...
View Full Document

Ask a homework question - tutors are online