Unformatted text preview: ent vs. Time Display 1–350 ANSYS Verification Manual . ANSYS Release 9.0 . 002114 . © SAS IP, Inc. VM159: Temperature-controlled Heater Overview Reference: Self-checking (Response Follows Input Request) Analysis Type(s): Transient Thermal Analysis (ANTYPE = 4) Element Type(s): Control Elements (COMBIN37) Convection Link Elements (LINK34) Thermal Mass Elements (MASS71) Input Listing: vm159.dat Test Case An assembly consisting of a heater with capacitance C1 and surface area A1 is surrounded by a box having capacitance C2 and surface area A2. The box is initially at a uniform temperature To. The heater, which supplies heat at a rate q, is turned on and remains on until the surrounding box temperature reaches a value Toff. The heater then switches off until the box temperature lowers to Ton and then switches on again. Determine the temperature response of the box and the heater status vs. time. Figure 159.1 Temperature-controlled Heater Problem Sketch Material Properties C1 = 2.7046 x 10-4 Btu/°F Geometric Properties A1 = 8....