Unformatted text preview: fined to be zero. An iterative solution is required. A friction factor of 0.025 (input for MU) is assumed for a starting value. ANSYS Verification Manual . ANSYS Release 9.0 . 002114 . © SAS IP, Inc. 1–280 VM124 Results Comparison Target ANSYS Ratio w, lbfsec/ft 0.898 0.930[1] 1.04 Re 1.94 x 105 2.01 x 105 1.04 1. w is given by nodal flow at node 1. ANSYS Verification Manual . ANSYS Release 9.0 . 002114 . © SAS IP, Inc. 1–281 VM125: Radiation Heat Transfer Between Concentric Cylinders Overview Reference: F. Kreith, Principles of Heat Transfer, 2nd Printing, International Textbook Co., Scranton, PA, 1959, pg. 260. Analysis Type(s): Thermal Analysis (ANTYPE = 0) AUX12 (Radiation View Factor Utility) Element Type(s): 2-D Conduction Bar Elements (LINK32) Superelement (or Substructure) (MATRIX50) Input Listing: vm125.dat Test Case Two long concentric cylinders are held at constant temperatures T1 and T2. Determine the rate of radiative heat transfer between the cylinders. Figure 125.1 Concentric Cyl...