Unformatted text preview: analytical solution above. ANSYS Verification Manual . ANSYS Release 9.0 . 002114 . © SAS IP, Inc. 1–535 VM230 The 2000 Latin Hypercube samples were post-processed to determine the logarithmic mean and logarithmic deviation of Y. A cumulative distribution function was plotted for Y showing the 95% confidence limit. This confirms that the distribution type of Y is log-normal, because the CDF is very close to a straight line. Figure 230.2 Cumulative Distribution Function (Probability vs. Log Y) Results Comparison Target ANSYS Ratio Mean Value of Y 2.6957898 2.6957898 1.000 Standard Deviation of Y 2.3744199 2.3744198 1.000 1–536 ANSYS Verification Manual . ANSYS Release 9.0 . 002114 . © SAS IP, Inc. VM231: Piezoelectric Rectangular Strip Under Pure Bending Load Overview Reference: V. Z. Parton, B. A. Kudryavtsev, N. A, Senik, Applied Mechanics: Soviet Review, Vol. 2: Electromagnetoelasticity, pg. 28. Analysis Type(s): Static Element Type(s): 2-D Coupled-Field Solid Elements (PLANE13) Input Listing: vm231.dat Test Case A piezoceramic (...