Unformatted text preview: Im V ρJRe s + j ρJ s Z= = I I I Re Im where V = voltage drop, J s and J s are real and imaginary components of the source current density (obtained from the solution results in the database file). The real component of the impedance represents the AC resistance Rac per unit length. The DC resistance per unit length Rdc is calculated as ρ/A. The AC/DC power loss ratio is calculated as Rac/Rdc. Results Comparison Target[1] ANSYS Ratio Re 10183 10123.55 0.994 J Im s 27328 27337.36 1.000 Impedance (Ohm/m) x 106 - 174.7 + j471.3 - Loss Ratio 2.33t[1] 2.39 1.025 Js 1. Target solution based on graphical estimate. ANSYS Verification Manual . ANSYS Release 9.0 . 002114 . © SAS IP, Inc. 1–417 VM185 Figure 185.2 Flux Lines Figure 185.3 Total Current Density 1–418 ANSYS Verification Manual . ANSYS Release 9.0 . 002114 . © SAS IP, Inc. VM185 Figure 185.4 Eddy Current Density ANSYS Verification Manual . ANSYS Release 9.0 . 002114 . © SAS IP, Inc. 1–419 VM186: Transient Analysis of a Slot Embedded Conductor Overview Refer...