Unformatted text preview: 4 " V ¢ '  & ¢ ¢ 2  ) ' 3#10(% %#! & $" Material Properties k = 0.54 Btu/hr-ft-°F ρ = 144 lb/ft3 c = 0.2 Btu/lb-°F h = 5 Btu/hr-ft2-°F Geometric Properties = 1 ft Loading To = 100°F Tg = 1600°F Analysis Assumptions and Modeling Notes The problem is first solved using LINK32 elements. A 1 ft2 area is used for the convection and conduction elements. Node 12 is given an arbitrary location. Automatic time stepping is used. The initial integration time step (ITS) chosen (14.5/80 = 0.18125 hr) is larger than the minimum ITS recommended; ITS ≈ δ2/4 α, where δ is the conduction element length (0.1 ft) and a is the thermal diffusivity (k/ρc = 0.01875 ft2/hr). POST26 is used to obtain the total heat transferred to the wall. ANSYS Verification Manual . ANSYS Release 9.0 . 002114 . © SAS IP, Inc. 1–247 VM110 Results Comparison Time = 14.5 hr Target[1] ANSYS Ratio[1] T, °F (node 1) 505. 507. 1.00 T, °F (node 3) 550. 549. 1.00 T, °F (node 5) 670. 675. 1....