Unformatted text preview: ANSYS revisions. ANSYS Verification Manual . ANSYS Release 9.0 . 002114 . © SAS IP, Inc. 1–461 VM203 Results Comparison Target ANSYS Ratio 45.9 46.30[1] 1.009 3401.8 3595.0[2] 1.057 Frequency f (Hz) 2 Peak Deflection PSD (mm /Hz) 1. From modal analysis solution 2. Peak amplitude (x106) from Harmonic analysis results using POST26 The peak one-sigma standard deviation from spectrum analysis (102.18 mm) agrees with the value from Harmonic analysis (108.16 mm), (No closed form solution is available from the reference for this entity.) Figure 203.2 Harmonic Response to Uniform PSD Force 1–462 ANSYS Verification Manual . ANSYS Release 9.0 . 002114 . © SAS IP, Inc. VM204: Solid Model of an Axial Bearing Overview Reference: Any basic geometry text Analysis Type(s): Solid Modeling Boolean Operations Element Type(s): None Input Listing: vm204.dat Test Case Find the volume of the axial bearing shown below. Figure 204.1 Axial Bearing Problem Sketch Analysis Assumptions and Modeling Notes The model is created entirely using only geometric primitives and solid model Boolean operations. A glue operation is used to provide continuity between model entities. ANSYS Verification Manual . AN...