Unformatted text preview: cations are arbitrarily selected as coincident. The flow rate (w) is input as a real constant, so MU is not required to be input. The nonlinear material property table is used to input the friction factor table and the flow-dependent film coefficient. Since the heat transport rate is calculated at the element inlet, an extra element is extended beyond the tube exit to obtain qout. POST1 is used to report the required quantities. Results Comparison Target ANSYS Ratio To , °F 123.0 122.55[1] 1.00 qin , Btu/hr 113.28 113.44[2] 1.001 qout , Btu/hr 139.33 139.02[2] 1.000 1. Temperature at Node 17. 2. qin and qout are obtained from the heat transport rates of elements 1 and 9, respectively. ANSYS Verification Manual . ANSYS Release 9.0 . 002114 . © SAS IP, Inc. 1–285 VM127: Buckling of a Bar with Hinged Ends (Line Elements) Overview Reference: S. Timoshenko, Strength of Material, Part II, Elementary Theory and Problems, 3rd Edition, D. Van Nostrand Co., Inc., New York, NY, 1956, pg. 148, article 29. Analysis...