EE 313 –Design Problem Last names between Q and Z Fall 2010 Due Tuesday, November 23 rd . Accepted without penalty by November 30 th . A balanced, three-phase, Y-connected source has a line voltage of 300 Vrms. The source frequency is 60 Hz. The balanced, three-phase loads have the following characteristics: Z Δ 1 : P 1 = 27 kW and Q 1 = +36 kVAR Z Δ 2 : 1.25 50º Ω Z y3 : PF 3 = 0.25 lagging and I p3 = 50 A rms Z y4 : S 4 = 12 60º kVA 1. Determine the phasor value of each impedance and the current for each load. 2. Determine the total line current, I aA . 3. Determine the total complex power, average power, and reactive power delivered by the
Background image of page 1
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: source to the loads. 4. What is the power factor of the three loads combined? 5. It is necessary to add a parallel load in the configuration to the circuit to change the power factor of all loads combined to 0.875 lagging. The line voltage and total average power delivered by the source may not change. What are the impedance and the component value of this load? 6. What is the power factor of the additional load? 7. What is the power factor of the four loads combined?...