3adw000072r0601 dcs600 system description e f

ip 00 enclosed converters ip 20213141 paint finish

Info iconThis preview shows page 1. Sign up to view the full content.

View Full Document Right Arrow Icon
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: Converter module: Enclosed converter: Environmental limit values Permissible cooling air temperature - at converter module air inlet: 0 to +55°C with rated DC current: 0 to +40°C w. different DC curr. acc. Fig. 2.1/2: +30 to +55°C - Options: 0 to +40°C Relative humidity (at 5...+40°C): 5 to 95%, no condensation Relative humidity (at 0...+5°C): 5 to 50%, no condensation Change of the ambient temp.: < 0.5°C / minute Storage temperature: -40 to +55°C Transport temperature: -40 to +70°C Pollution degree (IEC 60664-1, IEC 60439-1): 2 Site elevation: <1000 m above M.S.L.: >1000 m above M.S.L.: 100%, without current reduction with current reduct., see Fig. 2.1/1 Size Sound pressure level LP Vibration (1 m distance) as module enclosed conv. as module C1 59 dBA 57 dBA 0.5 g, 5...55 Hz C2 75 dBA 77 dBA A5 73 dBA 78 dBA 1 mm, 2...9 Hz A6 75 dBA 73 dBA 0.3 g, 9...200 Hz A7 82 dBA 80 dBA NCS 170 4 Y015R light grey RAL 7035 Current reduction to (%) enclosed conv. g, 2...150 Hz g, 2...150 Hz g, 2...150 Hz g, 2...150 Hz g, 2...150 Hz Current reduction to (%) 110 100 90 100 80 90 70 80 60 50 1000 2000 3000 4000 Fig. 2.1/1: Effect of the site elevation above sea level on the converter’s load capacity. 70 5000 m 30 Regulatory Compliance The converter module and enclosed converter components are designed for use in industrial environments. In EEA countries, the components fulfil the requirements of the EU directives, see table below. European Union Directive Manufacturer's Assurance Machinery Directive 98/37/EEC 93/68/EEC Low Voltage Directive 73/23/EEC 93/68/EEC EMC Directive 89/336/EEC 93/68/EEC Harmonized Standards Conver ter module Enclosed conver ter Declaration of Incor poration EN 60204-1 [IEC 60204-1] EN 60204-1 [IEC 60204-1] Declaration of Conformity EN 60146-1-1 [IEC 60146-1-1] EN 50178 [IEC --] see additional IEC 60664 EN 60204-1 [IEC 60204-1] EN 60439-1 [IEC 60439-1] EN 61800-3 ➀ [IEC 61800-3] EN 61800-3 ➀ [IEC 61800-3] ➀ in accordance with 3ADW 000 032 ➀ in accordance with 3ADW 000 032/ 3ADW 000 091 Declaration of Conformity (Provided that all installation instructions concerning cable selection, cabling and EMC filters or dedicated transformer are followed.) 35 40 45 50 55°C Fig. 2.1/2: Effect of the ambient temperature on the converter module load capacity. North American Standards In North America the system components fulfil the requirements of the table below. Rated supply voltage Standards Converter module Enclosed converter to 600 V UL 508 C Power Conversion Equipment CSA C 22.2 No. 14-95 Industrial Control Equipment, Industrial Products Available for converter modules including field exciter units. Types with UL mark: • see UL Listing www.ul.com / certificate no. E196914 • or on request UL/CSA types: on request > 600 V to 1000 V EN / IEC types: on request (for details see table on the left) EN / IEC xxxxx see table on the left Available for converter modules including field exciter units. II F 2-3 3ADW000072R0601 DCS600 System descrip...
View Full Document

Ask a homework question - tutors are online