3adw000072r0601 dcs600 system description e f

81 main control word switch speed ramp input to

Info iconThis preview shows page 1. Sign up to view the full content.

View Full Document Right Arrow Icon
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: modes 4 and 5 1: force speed controller output according in torque selector modes 4 and 5 10 to reserved (reserved) 15 reserved (reserved) Note 1: Changes of the commanded drive direction get actice only in the state RDY_RUN; reversal of a running drive by means of this control bit is not possible. Note 2: Settings for DO1...DO3 are default. Table 3.8/3: Auxiliary Control Word 2 II F 3-11 3ADW000072R0601 DCS600 System description e f Main Status Word (8.01) Auxiliary Status Word (8.02) Bit Name Function 0 RDY_ON ready to close the contactor 1 RDY_RUN ready to generate torque 2 RDY_REF 3 Bit Name Function 0 LOGG_DATA_READY Contents of data logger is readable torque control operating (running) 1 OUT_OF_WINDOW Speed actual value is outside of the defined window TRIPPED indication of fault in DCS600 MultiDrive 2 EMERG_STOP_COAST Emergency stop function has failed 4 OFF_2_STA_N 1: No OFF2_N active 3 reserved (reserved) 5 OFF_3_STA_N 1: No OFF3_N active 6 ON_INHIBITED Switch on inhibited ON_DISABLED ALARM indication of alarm in DCS600 MultiDrive 4 7 External interlocking ON INHIBIT 1 or ON INHIBIT 2 (ORed digital inputs selected by 15.14 and 15.15 ) prevent the run 8 AT_SETPOINT Setpoint/act.value monitoring in the tolerance 5 SYNC_RDY Position counter synchronous ready status 9 REMOTE 1:Remote control / 0:Local control 6 FEX1_ACK acknowledge of 1st Fex FEX2_ACK acknowledge of 2nd Fex ABOVE_LIMIT speed treshold value (50.10) reached 7 10 8 reserved (reserved) 9 LIMITING Drive is limiting, see signal 8.03 10 TORQ_CONTROL Drive is torque controlled 11 ZERO_SPEED Motor speed actual is zero 12 EMF-SPEED EMF speed feedback selected if SPEED FB SEL (50.03) = 1 13 FAULT_OR_ALARM Fault or alarm of drive 14 DRIVE_DIR_ASW Negative drive direction active 15 AUTO_RECLOSING auto reclosing logic activated 11 reserved (reserved) 12 reserved (reserved) 13 reserved (reserved) 14 reserved (reserved) 15 reserved (reserved) Table 3.8/4: Main Status Word Table 3.8/5: II F 3-12 3ADW000072R0601 DCS600 System description e f Auxiliary Status Word Digital inputs/outputs Depending on the drive modes there are different possibilities for digital inputs and outputs. Digital Inputs Input Signal DI 1 DI 1 DI 2 DI 2 DI 3 DI 3 DI 4 DI 4 DI 5 DI 5 DI 6 DI 6 DI 7 DI 7 DI 8 DI 8 Armature converter mode use Description Field converter mode Digital inputs Armature converter mode (DCS 600) Input Signal use DI 2 ACK_OVERVOLT fix DI 1 DI 1 DI 3 DI 3 DI 4 DI 4 DI 5 DI 5 DI 6 DI 6 DI 7 12.13 ACK Conver ter fan 12.14 ACK Motor fan 12.15 ACK Main contactor 12.16 Emergency STOP 15.13 electrical disconnect configurable 15.14 ON INHIBIT 1 → 15.15 ON INHIBIT 2 15.18 ACK DC breaker 15.20 ACK DYN brake 28.18 Klixon (motor 1 trip) 28.25 Klixon (motor 2 trip) if COMMAND SEL 15.22 = 1 (local I/O) then DI 6 = Reset; DI 7 = ON; DI 8 = RUN Table 3.8/6: Digital Inputs DI 7 DI 8 DI 8 Description Acknowledge over voltage protection DCF 505/506 12.13 ACK Conver ter fan 12.14 ACK Motor fan 12.15 ACK Main contactor 12.16 Emergency STOP 15.13 electrical disconnect 15.14 ON INHIBIT 1 configurable 15.15 ON INHIBIT 2 15.18 ACK DC breaker → 15.20 ACK DYN brake 28.18 Klixon (motor 1 trip) 28.25 Klixon (motor 2 trip) Note: Do not select DI 2 for these functions! if COM...
View Full Document

This note was uploaded on 08/22/2011 for the course EEE 230 taught by Professor Subramanian during the Spring '07 term at University of California, Berkeley.

Ask a homework question - tutors are online