3adw000072r0601 dcs600 system description e f

All parameters can be transferred to the pc and be

Info iconThis preview shows page 1. Sign up to view the full content.

View Full Document Right Arrow Icon
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: riveWindow (PC utility), fieldbus or overriding control system. Changed parameters or pointers are stored immediately in the non-volatile flash PROM. All parameters can be transferred to the PC and be stored on a data medium by using DriveWindow. II F 3-6 3ADW000072R0601 DCS600 System description e f 99.02 99.05 3ADW000072R0601 DCS600 System description e f PANEL CDP312 or DRIVES WINDOW LOCAL CTRL INPUT DIGITAL TACHO PULSE ENCODER INTERFACE AI1 MOTOR NOM VOLTAGE MOTOR NOM SPEED EMF ENCODER PULSE NR 50.03 50.04 DIGITAL OUTPUTS CONTROL 7.02 8.05 8.02 8.01 7.03 LIMITER USED SPEED REF MINIMUM SPEED 50.13 20000 = Speed scaling 50.06 SP ACT FTC FILTER 1.04 1.01 ON OFF2 OFF3 RUN RAMP_OUT_ZERO RAMP_HOLD RAMP_IN_ZERO RESET INCHING1 INCHING2 VALID_COMMAND B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 HOLD_NCONT WINDOW_CTRL BAL_NCONT SYNC_COMMAND SYNC_DISABLE RESET_SYNC_RDY JOG_REF DIG_OUT4 DIG_OUT5 DIG_OUT6 RESTART_DLOG TRIGG_LOGGER RAMP_BYPASS BAL_RAMP_OUT DYN_BRAKE_ON_APC BAL RAMP REF BAL RAMP OUT DRIVE_DIR SPEED_EXT DIG_OUT_7 DIG_OUT_8 2.16 B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 RDYON RDYRUN RDYREF TRIPPED OFF_2_STA OFF_3_STA ON_INHIBIT ALARM AT_SETPOINT REMOTE ABOVE_LIMIT + + 2.18 2.02 B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 SPEED REF 4 SPEED REF 3 ACC COMPFILT TIME ACC COMP DER TIME ACCELERATION COMPENSATION WINDOW WIDTH NEG WINDOW WIDTH POS WINDOW INTG ON SPEED ERROR FILT + + LIMITING TORQ_CONTROL ZERO_SPEED EMF_SPEED FAULT_OR_ALARM DRIVE_DIR_ASW AUTO_RECLOSING ON_DISABLED SYNC_RDY FEX1_ACK FEX2_ACK LOGG_DATA_READY OUT_OF_WINDOW EMERG_STOP_COAST B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 DI9 DI10 DI11 DI12 DI13 DI14 DI15 CONV FAN ACK MOT FAN ACK MAIN CONT ACK configurable configurable configurable configurable configurable 8.05 DI STATUS WORD DI STATUS WORD PI D SPC TORQMIN SPC TORQMAX BAL_NCONT BAL REF 24.02 DROOP RATE 24.04 KPS TIS MIN SPEED KPS TIS MAX SPEED 24.18 KPS VAL MIN SPEED 24.13 TIS motor speed KPS VAL MAX SPEED SPC TORQMIN SPC TORQMAX LIMITER TORQUE INTEG REF TORQ REF 2 KPS TIS MAX SPEED TIS VAL MIN SPEED KPS, TIS KPS KPS TIS MIN SPEED KPS TORQUE DER REF TORQUE PROP REF dcs_600\docu\fig_1a.dsf DERIV. FILT TIME DERIVATION TIME 24.20 24.12 TIS VAL MIN SPEED 24.19 TIS INIT VALUE 24.17 TIS KPS WP FILT TIME 24.10 24.09 24.06 KPS WEAKPOINT KPS MIN 24.03 24.05 KPS 20.08 20.07 ACW B8 SPEED ERROR 24.11 NEG 2.03 2.07 PID- CONTROLLER SPEED CONTROL TORQ ACC COMP REF MCW Bx = MAIN CONTROL WORD (7.01) ACW Bx = AUX CONTROL WORD (7.02) B = bit 23.09 23.08 23.07 23.06 (-1) FILTER WINDOW SPEED STEP 23.10 Speed limits 135.02 and 135.04 apply here also 24.15 24.14 8.02 AUX STATUS WORD ASW SPEED ACTUAL SPEED CORRECTION 23.04 MCW B8, B9 ACW B12 8.01 MAIN STATUS WORD MSW RAMP BYPASS ACW B2 DV/DT VARIABLE SLOPE RATE VARIABLE SLOPE 22.08 ACW B3 22.07 22.06 SHAPE TIME EME STOP RAMP 22.04 22.05 DECELER TIME RAMPTIME SCALE 7.03 AUX CONTROL WRD 2 B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 0 ACCELER TIME HOLD 22.03 0 RA...
View Full Document

Ask a homework question - tutors are online