Unformatted text preview: • Recommendation: Field voltage ~ 0.9 * UV ⎛ 100% + TOL ⎞ U A = UV * ⎜ ⎟ * 0.9 ⎝ 100% ⎠ TOL = tolerance of line voltage in % UV = Line voltage • Recommendation: Field voltage 0.6 to 0.8 * UV SDCS-FEX-1 SDCS-FEX-2A II F 2-9 3ADW000072R0601 DCS600 System description e f DCF 503A DCF 600 • Half controlled thyristor/diode bridge (1-Q). • Microprocessor control with the control electronics being supplied separately (115...230 V/1-ph). • Construction and components have been designed for an insulation voltage of 690 V AC. • Output voltage UA: This field power converter is used mainly for armature converters with rated currents of 2050 to 5200 A. It is a modified armature circuit converter. • Output voltage UA respectively Udmax 2-Q : see table 2.2/1. • Recommendation: Field voltage 0.5 to 1.1 * UV • The three-phase field supply converters DCF 600 needs a separate active overvoltage protection unit DCF 506 for protecting the power part against too high voltages. The overvoltage protection unit DCF 506 is suitable for 2-Q converters DCF 601 and for 4-Q converters DCF 602. ⎛ 100% + TOL ⎞ U A = UV * ⎜ ⎟ * 0.9 ⎝ 100% ⎠ TOL = tolerance of line voltage in % UV = Line voltage • Recommendation: Field voltage 0.6 to 0.8 * UV DCF 504A • Fully controlled antiparallel thyristor bridges (4-Q). • With this unit fast response excitation / de-excitation and field reversal is possible. For fast response excitation an appropriate voltage reserve is necessary. In steady-state condition, the fully controlled bridge runs in half controlled mode to keep the voltage ripple as low as possible. With a fast changing field current, the bridge runs in fully controlled mode. • Same design as DCF 503A Assignment Field supply converter to Overvoltage protection unit Field supply converter for motor fields DCF60x-0025-51 ... DCF60x-0140-51 DCF506-0140-51 DCF60x-0200-51 ... DCF60x-0520-51 DCF506-0520-51 DCF503A/504A Unit type Overvoltage Protection DCF601/602 DCF506-140-51, without cover Output current IDC ➀ [A] Supply voltage [V] Installation site SDCS-FEX-1-0006 SDCS-FEX-2A-0016 0.02...6 0.3...16 110V -15%...500V/1-ph +10% 110V -15%...500V/1-ph +10% internal internal DCF 503A-0050 DCF 504A-0050 0.3...50 0.3...50 110V -15%...500V/1-ph +10% 110V -15%...500V/1-ph +10% external external ⎫auxiliary supply (115...230V) if necessary via matching trans⎬former; external fuse; Dimensions HxWxD: 370x125x342 [mm] ⎭ see table 2.2/2 200V...500V/3-ph external are based on the hardware of the DCS 600 and additional hardware components (DCF 506); auxiliary supply (115/230 V) DCF 60x-xxxx-41/51 Remarks external fuse, 6 A ⇒ IFrated ext. fuse, reactor; for C1: 0.3 ... 8 A ➀, not to be used for A6/A7 mod.! ➀ Current reduction see also 2.1 Environmental conditions Fig.: 2.1/1 and 2.1/2 Table 2.4/1: Data field converter units II F 2-10 3ADW000072R0601 DCS600 System description e f 2.5 Options for DCS 600 MultiDrive converter modules In-/output s...
View Full Document

This note was uploaded on 08/22/2011 for the course EEE 230 taught by Professor Subramanian during the Spring '07 term at University of California, Berkeley.

Ask a homework question - tutors are online