1926.1051(a) Subpart X 19” and over Stairways and Ladders A Stairway or Ladder is Required
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full Document Right Arrow Icon
Subpart X 1926.1051 (a)(2) less than 25 workers 1 Ladder Required
Background image of page 2
1926.1051 (a)(2) A double-cleated ladder 25 or more workers Or Severe two- way traffic
Background image of page 3

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full Document Right Arrow Icon
1926.1051 (a)(2) Two or more separate ladders 25 or more workers Or Severe two- way traffic
Background image of page 4
1926.1053 L 3’ Good Footing Stable/Level Surface Setting Up a Ladder Ladder tied off L/4 No Debris
Background image of page 5

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full Document Right Arrow Icon
Ladders should be able to support 4 times the intended load
Background image of page 6
When Ascending or Descending: Face the Ladder One Hand Free Don’t Carry Loads
Background image of page 7

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full Document Right Arrow Icon
10” to 14” o.c. Ladder Step
Background image of page 8
Background image of page 9

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full Document Right Arrow Icon
Background image of page 10
Background image of page 11

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full Document Right Arrow Icon
Background image of page 12
Background image of page 13

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full Document Right Arrow Icon
Background image of page 14
Background image of page 15

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full Document Right Arrow Icon
Background image of page 16
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: Stool 8” to 12” o.c. 16” min. (11 ½” for portable ladders) Fixed Ladder Clearances: 7” minimum 30” Min. Caged if over 24’ high Temporary Stairs 12’ 30” Landing Width = 22” (Minimum) >30” or 4 risers Subpart X 1926.1052(c) (1) (i) At least one handrail required Subpart X 30” to 37” Height of Handrails Temporary Handrails 3” (Min.) Subpart X When the stairrail system also serves as the handrail 36” to 37” Height of Handrails 1926.1052 (c) (1) (ii) • At least one stairrail system along each unprotected edge...