EML 6417 Solar Utilization Homework No. 3 Due September 18, 2009 1. A heat exchanger in a solar storage tank is to deliver heat to the storage media at a rate of 630,000 btu/h (185kW). The fluid from the solar collector bank is water with a minimal concentration of corrosion inhibitors and no glycol for freeze protection. The water enters the heat exchanger at 180 deg F(82deg C) and leaves at 160 deg F(71deg C). What flow rate of solar heated fluid is required, gpm? If the pipe servicing the heat exchanger with this solar heated fluid is schedule 40 steel pipe, what pipe size would you recommend?(since the fluid is circulated with a pump, sizing based on LCC would be the best). 2. The collector loop to the storage tank described above is made up of the following components: 420 feet of pipe (even though this pipe might be made up of different sizes based on the flow it carries, assume the average pressure loss factor is 2.5 ft/100ft for all this pipe) 10 elbows (long radius) at 2.5 ft/100 ft pressure loss factor
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Background image of page 2
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: 6 gate valves, GV, at 2.5 ft/100 ft pressure loss factor 1 horizontal swing check valve (used to only allow flow in one direction),CKV at 2.5 ft/100 1 Y-strainer (used to filter trash out of the water), YS at 2.5 ft/100ft 2 flexible couplings (assume same equiv. ft as a regular coupling), FC at 2.5 ft/100ft 1 air separator with a head loss of 5 ft ( used to separate entrained air from the system),AS 1 storage tank heat exchanger with a head loss of 10 ft 1 solar collector flat plate collector array with a head loss of 10 ft. (includes balancing valves) 1 base mounted pump Select a Bell and Gossett series 1510 base mounted pump for this system. Print out the selection and pump curve to submit with your homework submittal. Just for fun, take the developed length of pipe (420 ft) multiply by 1.2 and add the pressure drops for the AS, storage tank and collector array and see if you get about the same answer. Solar Collector Array Solar HHW pump FC FC GV GV GV GV GV GV CKV Thermal Storage AS...
View Full Document

Page1 / 2

homework no. 3 2009 - 6 gate valves, GV, at 2.5 ft/100 ft...

This preview shows document pages 1 - 2. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online