solar utlization lec 14 domestic hot water

solar utlization lec 14 domestic hot water - Solar...

Info iconThis preview shows pages 1–7. Sign up to view the full content.

View Full Document Right Arrow Icon
1 Solar Utilization Potable Water System Sizing: Designer must comply with applicable portions of the Standard Plumbing Code and with local utility requirements (Florida Building Code) Some institutions (e.g. UF) may have their own requirements Other organizations that have standards applicable to plumbing: ANSI(American National Standards Institute), ASCE, ASPE, ASSE (American Society of Sanitary Engineering), AWWA (American Water Works Association), MCAA, NFPA(National Fire Protection Association), UL, etc. H. A. . . Ingley PhD,PE
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
2 Potable Water System Sizing: Components of Domestic Valves Strainers Wall Hydrants Water Hammer Arresters Backflow Preventors Meters and Gauges Relief Valves Trap Primers Access Doors H. A. . . Ingley PhD,PE
Background image of page 2
3 Solar Utilization Potable Water System Sizing: Specifications of materials depends on application but in general for commercial or institutional domestic water systems: Interior water piping: above grade-copper tube, type L, hard drawn temper; wrought copper fittings with solder joints and below grade- copper tube, Type L, soft annealed temper; no joints below floor H. A. . . Ingley PhD,PE
Background image of page 3

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
4 Solar Utilization Potable Water System Sizing: Exterior water piping: Copper tube; Type L, hard drawn temper; wrought-copper fittings, solder joints Polyvinyl chloride pipe(PVC), schedule 40, PVC socket fittings, solvent cement joints All solder joints should meet requirements of the code (lead free may be an issue) Deionized water is piped in schedule 40 PVC, NSF labeled. H. A. . . Ingley PhD,PE
Background image of page 4
5 Solar Utilization Potable Water System Sizing: Factors that determine size of water supply: Available water pressure, psig Type and length of piping Height of building Flow pressure required at most remote fixture Type of fixtures (residential vs. commercial or institutional) Performance based pipe sizing method Tables…Tables….Tables….Tables….Tables H. A. . . Ingley PhD,PE
Background image of page 5

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
6 Solar Utilization Potable Water System Sizing:
Background image of page 6
Image of page 7
This is the end of the preview. Sign up to access the rest of the document.

Page1 / 32

solar utlization lec 14 domestic hot water - Solar...

This preview shows document pages 1 - 7. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online