H. Elizabeth Broome, M.D. UCSD Medical Center Clinical Laboratory Hematology Automated complete blood counts (CBC) Automated and manual leukocyte differential (Diff) Marrow examination Smears Tissue biopsy and clot
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Validation of CBC Blood counts often critical for diagnosis Automated counts are accurate and reliable, but they have limitations Medical technologists and physicians validate automated blood counts by: Comparing with previous results Determining if they are physiologically possible Correlate with scatterplots, histograms, blood smears, and clinical history
Background image of page 2
Physiologic variation physiologic variation due to age, sex, altitude, pregnancy, time of day, posture Hgb and cell counts are highest in the morning, lowest in the evening with a mean difference of 8-9% Cell counts increase several % upon standing from a recumbent position
Background image of page 3

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Normal Values
Background image of page 4
Typical Automated Cell Counter Operation Sample is aspirated and split into three segments to measure: White blood count (WBC) and differential after lysis of red cells Hemoglobin by spectrophotometry Red blood cell (RBC) and platelet (PLT) counts Two basic mechanisms to identify different cells: optical (flow cytometry) and impedance
Background image of page 5

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
WBC and Differential by Optical/ Flow Cytometry
Background image of page 6
WBC and Sizing by Optical WBC and Sizing by Optical Measurements Measurements Insert Fig 3.4 from CellDyn manual
Background image of page 7

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Complexity” Measurement by
Background image of page 8
Image of page 9
This is the end of the preview. Sign up to access the rest of the document.

This note was uploaded on 09/14/2011 for the course PHARM HEM taught by Professor Staff during the Spring '11 term at UCSD.

Page1 / 36

CBCmarrowExam - Clinical Laboratory Hematology H Elizabeth...

This preview shows document pages 1 - 9. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online