Unformatted text preview: 1 Automatic Fire Suppression Systems FPST 2243 Unit 3 Plan submittal requirements 9/28/11 A typical drawing 1 5-6 1 4-6 1 10-0 2 8-4 9/28/11 General requirements North should always be at the top or left side of the drawing. All lettering and numbers should be written so they can be read from the bottom or right hand side of the drawing. Pipes should be drawn as single lines and should be the darkest lines on the drawing. Walls and partitions should be double lines. These lines should not be as dark as the pipes, but should be darker than beams or joists. 9/28/11 9/28/11 General requirements Beams or joists should be drawn with very light lines. A center line is often used to represent beams. A dotted line is often used to represent joists. All lines, sprinklers, valves, etc. must be drawn using straight edges and templates. Floor plans are ordinarily drawn to a scale of 1 inch equals 8 feet. Pipe diameter is to be indicated on the top of a section of a pipe, with pipe length shown below the pipe. Do not use' or" to indicate feet and inches. This is not necessary if your numbers are in the correct location. 9/28/11 9/28/11 Real pipe length calculation The take out for the elbow would be:11/16" The take out for the tee would be: 11/16" Cut length = l0 f. - 11/16" - 11/16" = 9' - 10 5/8" Often the cut length of pipe will be shown on sprinkler drawings in parenthesis below the center to center separation as follows: 1 5-6 1 10-0 " x 1" Elbow 1 " x 1" x " Tee Upri ght Spri nkl ers Pendent Spri nkl ers Spri nkl ers of ot her t han ordi nary t emperat ure rat i ng w i t h rat i ng i ndi cat ed . Upri ght Spri nkl ers on spri gs Pendent Spri nkl ers on drops Si dewal l Spri nkl ers Pendent Spri nkl ers on spri gs 212 o 286 o I nsi de Out si de El ect ri c Bel l Wat er Mot or Gang Hor n I nspect or s t est connect i on f or wet syst em ( must i ndi cat e di mensi ons) I nspect or s t est connect i on f or dr y syst em 1 2- 0 1X6- 0 DN Symbols in sprinkler design 9/28/11 Symbols in sprinkler design Wall Ri ser Ni ppl es on Crossmai n...
View Full Document

Page1 / 36

FPST2243_02_ plan submital requirements - 1 Automatic Fire...

This preview shows document pages 1 - 8. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online