79 freeze). For all the cases, the dynamic load test closer to the static load test was performed after the load test (i.e. the static capacity was compared to the Beginning of Restrike). Other requirements include having a measured skin capacity by mean of a pull out static load test or Osterberg load cell test. For each pile, it was required to know both geometric and driving parameters, such as, wave speed, pile length below the gages, cross-sectional area, and material modulus. Based on the latter requirements, 18 test pile were considered. Table 7-1 summarizes general information of each load test pile. The pile population represents 9 sites and 3 diameters, while the range of depths of the piles below the gages varies from 9.15 to 34.45 meters. Only one test pile is from a location outside the State of Florida. Automating the Suggested Method A Fortran program was developed in order to simplify the calculation process.