95_HWKTTE 4004c - 85 8000 7000 6000 5000 4000 3000 Number...

Info icon This preview shows pages 1–2. Sign up to view the full content.

View Full Document Right Arrow Icon
85 0 1000 2000 3000 4000 5000 6000 7000 8000 0 1000 2000 3000 4000 5000 6000 7000 8000 Davisson Capacity (kN) Number of Cases = 18 Mean = 1.09 Std. Dev. = 0.35 COV = 0.32 Figure 7-7. Davisson Capacity vs. PDA Rmax Capacity (used in Method 1) The total dynamic capacity was obtained using the Case solution for time T 1 located at the maximum force entering the pile. Then, the tip and the tip to skin ratio were calculated using Equations 7-2 and 7-3. With this tip to skin ratio and the PDA R max the static skin and tip capacity for the Method 1 were calculated. A series of figures show the results from the three methods studied, i.e. CAPWAP, Method 1 (using PDA Rmax), and the suggested method in comparison with the measured capacity. Figure 7-5 shows the Davisson’s capacity versus the estimated capacity by the suggested method. The CAPWAP estimated capacity versus the Davisson’s capacity is presented in Figure 7-6, and the same relation for the PDA estimated capacity is presented in Figure 7-7.
Image of page 1

Info icon This preview has intentionally blurred sections. Sign up to view the full version.

View Full Document Right Arrow Icon
86 Analysis of Total Capacity Predictions For the total capacity analysis, only 18 cases out of 23 cases were used.