147 y = 0.4487x R 2 = -0.0733 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 Davisson Capacity (kN) Gates EOD Capacity (kN) Figure H-1. Davisson Capacity vs. Gates EOD Capacity 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 Davisson Capacity (kN) Davisson Capacity / Gates EOD Capacity Cases=74 Mean=1.74 Standard Dev.=0.79 Figure H-2. Measured Over Predicted Capacity for Gates Method at EOD
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
148 Table H-1. φ Values Evaluated for Gates – Overall (EOD) Span length Failure Probability p f / Reliability Index β Τ (m) Q D /Q L 2.50E-02 6.22E-03 1.22E-03 1.79E-04 1.96 2.5 3.03 3.57 9 0.52 0.884 0.681 0.527 0.406 15 1.00 0.848 0.653 0.505 0.389 18 1.06 0.845 0.651 0.503 0.388 27 1.58 0.822 0.633 0.490 0.377 36 2.12 0.806 0.621 0.481 0.370 45 2.64 0.796 0.613 0.474 0.365 50 3.00 0.790 0.608 0.471 0.363 60 3.53 0.783 0.603 0.467 0.359 Table H-2. ASD Design Safety Factor for Gates – Overall (EOD)