Set up weather data, select state and city. You do not have to select a simulation city but I used Jacksonville here.
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Open up a default space window.
Background image of page 2
Click on General Tab. Name the space, input floor area, ceiling height and adjust building wt. if necessary. Define the space usage …in this case office space. The ventilation OA requirement is set then for this usage. You can input your Own usage if you want And not use ASHRAE 62 Requirements.
Background image of page 3

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Click on Internals Tab and put in lights, equipment, people. Indicate activity level for people. Don’t forget to change ballast multiplier to 1.0 if your lighting input per square foot includes the Ballast already.
Background image of page 4
Click on the schedule and this window will pot up. Give the schedule a name. Use fractional for lights, people and equip.
Background image of page 5

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Click on Hourly Profile tab and click on profile one and define the schedule for lights, equipment and people. You can use a different schedule and profile for lights, people and equipment if you like.
Background image of page 6
In this case I used the same schedule for lights, people and equipment.
Background image of page 7

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Click on Walls, etc. tab and input gross wall area for each orientation and indicate number of windows. You can put “1” in for window quantity and then define the window size to include the total window area for that wall.
Background image of page 8
set up for wall 1. You can refer to
Background image of page 9

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Image of page 10
This is the end of the preview. Sign up to access the rest of the document.

This note was uploaded on 10/22/2011 for the course EML 4930 taught by Professor Staff during the Fall '08 term at University of Florida.

Page1 / 37

Carrier Hap input lecture - Set up weather data, select...

This preview shows document pages 1 - 10. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online