EXPERIMENT 2: ELECTROPHORESIS (INFORMAL) Data ____10___ / 15 pts Data Table: Direction and distance migrated as a function of pH. Note: This table should contain all the class data. Also, values should contain signs (+ or -) in front of them to indicate the direction. The table should also show the average and standard deviation for each pH. Points should be deducted if any of these items are missing. Table containing the experimentally determined and literature isoelectric point for BSA. Results ____21___ / 25 pts Plot of Average Distance Migrated vs. pH (10 points) Experimentally determined isoelectric point of BSA along with the literature pI of BSA (6 points) Deduction of the isoelectric point of BSA and a shoret explanation. 6 Questions ____44___ / 50 pts Question 1: 10 pts Question 2: 5 pts Question 3: 10 pts Question 4: 10 pts Question 5: 5 pts Question 6: 10 pts Style (organization, neatness, proper formatting etc.) ____10___ / 10 pts Point Deductions - _______ Score ___85____/ 100 pts
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
The Determination of the Isoelectric Point of the Protein Bovine Serum Albumin Francisco Andrade Jessica Booe 5/25/10 Wesley Storm CHEM 241L 402, Morehead Labs Room 301 Pledge
Background image of page 2
Results and Calculations: The goal of this experiment was to use electrophoresis to determine the isoelectric point of the protein bovine serum albumin. The isoelectric point is the pH value that leads to electric neutrality and results in no observed migration when electrophoresis is performed 1 . The class was divided into five groups, and each was assigned a pH value ranging from 4.00 to 7.00. The protein was placed on electrophoresis strips and subjected to an electric current which allowed it to move based on its electrical charge. The protein could move either towards the anode, the red terminal with a positive charge, or the cathode, the black terminal with the negative charge. The class data for this experiment is displayed in Table 1. pH Migration Distance (mm) Average Distance Migrated Calculated Standard Deviation Strip 1 Strip 2 Strip 3 Strip 4 4.00 +5 +5 +6.5 +5.5 +5.5 0.707 4.50 +3 +4 +5 +4 +4 0.707 5.00 -3.8 -3.6 -3.9 -3.7 -3.75 0.129 6.00 -15.0 -12.0 -14.0 -13.0 -13.5 1.29
Background image of page 3

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Image of page 4
This is the end of the preview. Sign up to access the rest of the document.

Page1 / 7

andrade2 - EXPERIMENT 2: ELECTROPHORESIS (INFORMAL) Data...

This preview shows document pages 1 - 4. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online