DATA
SHEET
Single-Stage Filters
FN 2030
General Purpose AC/DC EMI Filter with High Attenuation Performance
Rated currents from 1 to 30 A
High performance filter attenuation
High differential-mode attenuation
Optional medical versions (B type)
Optional safety versions (A type)
Optional enhanced performance versions
Optional overvoltage protection (Z type)
Performance indicators
Technical specifications
Rated voltage*
250 VAC, 50/60 Hz; 250 VDC
Operating frequency
DC to 400 Hz
Rated currents
1 to 30 A @ 40°C max.
High potential test voltage
P –> PE 2000 VAC for 2 sec (equiv. cap <88 nF)
P –> PE 2550 VDC for 2 sec (equiv. cap >88 nF)
P –> PE 2500 VAC for 2 sec (B types)
P –> N 1100 VDC for 2 sec
Temperature range (operation and storage)
-25°C to +100°C (25/100/21)**
Certified to
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 (applies to
AC and DC applications)
Flammability corresponding to
Terminal plastic for -06/-08 version: UL 94 V-0
Laces for -07 version: UL 94 VW-1
Grommet for -07 version: UL 94 V-0
Overvoltage category
II acc. IEC 60664-1
Pollution degree
2 acc. IEC 60664-1
Altitude
2000m (above derating applies)**
MTBF @ 40°C/230 V (Mil-HB-217F)
2,200,000 hours (1 to 10 A types)
1,200,000 hours (12 to 30 A types)
Surge pulse protection (Z type)
Helps compliance to IEC61000-4-5 (Differential Mode
only)
*
maximum RMS operating voltage at rated frequency or the maximum DC operating voltage
** for dedicated requests exceeding this specification (e.g. -40 °C or higher altitude) please contact your local
Schaffner Sales office
Approvals
Features and benefits
FN 2030 filters are designed for easy and fast chassis
mounting
FN 2030 B versions without capacitors to earth
comply to 1MOP for ME (medical equipment) acc.
IEC 60601-1
FN 2030 A versions with low capacitance to earth
for safety critical applications with a requirement for
low leakage currents
FN 2030 filters offer an optimized filter range for
high performance AC and DC applications , in same
compact size (M, N1 types)
All filters provide an exceptional conducted
attenuation performance, based on chokes with
high permeable core material and excellent thermal
behavior
The higher inductivity versus amperage offers
increased attenuation performance with same form
factor compared to FN 2010 and FN 2020 filter series
All FN 2030 filters can be delivered with optional
surge pulse protection (Z type).