8.2 – Average Power, Section 8-3 Summary Comparison: Results: Pav (mW) Analysis 28.800 Simulation 28.815 Measurement 27.26 Relative difference compared to analysis: Simulation 0.1% Measurement -5.3% Analytical Solution:
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
myDAQ Results: Function Generator setup:
Background image of page 2
Voltage, current, and phase difference:
Background image of page 3
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: Measured source voltage = 2.117 Vrms Measured source current = 1.525 Vrms / 100 Ω = 15.25 mArms Measured time shift = 60 μ s Calculated phase difference = 60 μ s × 1500Hz × 360 ° = 32 ° Calculated average power = 2.117 × 15.25e-3 × cos(32 ° ) = 27.26 mW...