Project Number 1 Section 07634 Heritage May 2003 Metal Soffits - Perforated SECTION 07634 METAL SOFFITS / Perforated PART 1 GENERAL 1.1 SUMMARY A. Includes But Not Limited To 1. Furnish and install metal soffit on Storage Building as described in Contract Documents. 1.2 SYSTEM DESCRIPTION A. Performance Requirements 1. Installed soffit system shall meet minimum required structural loading conditions when tested in accordance with Test Method No. 4 of AAMA Specification 1402-86. 2. Face finish shall meet performance requirements of Test Method No. 6 of AAMA Specification 1402.-86. Reverse side coating shall pass requirements of paragraphs 1.1 through 1.4 of Test Method No. 6. 1.3 WARRANTY A. Manufacturer's written 20 year guarantee for finish. PART 2 PRODUCTS 2.1 COMPONENTS A. Aluminum Soffit 1. Panels - a. 0.019 inch thick minimum. b. 'V' groove design complete with matching trim. c. Panels shall be interlocked full length of panel. d.