Project Number 1 Section 10213 Heritage May 2003 Stationary Metal Wall Louvers SECTION 10213 STATIONARY METAL WALL LOUVERS PART 1 GENERAL 1.1 SUMMARY A. Products Supplied But Not Installed Under This Section 1. Aluminum architectural louvers as described in Contract Documents B. Related Sections 1. Division 03 - Installation in concrete 2. Division 04 - Installation in masonry 3. Division 06 - Installation in framing PART 2 PRODUCTS 2.1 MANUFACTURED UNITS A. Weather-Proof Wall Louvers 1. 6063 T5 aluminum 2. Metal thickness minimum - a. 0.050 inch - Louvers up to 24 inches square b. 0.081 inch - Louvers over 24 inches either dimension 3. Flange type frame. 4. Louvers shall be sloped and shaped to prevent penetration of driving rains or snow. 5. Screens - 14x18 aluminum mesh. 6. Finish - a. Mill finish, with clear Methacrylate lacquer protection. a. Kynar 500 or Hylar 5000, color as selected by Architect. 7.