Chapter 1 Basics of Heat Transfer 1-138 The range of U-factors for windows are given. The range for the rate of heat loss through the window of a house is to be determined. Assumptions 1 Steady operating conditions exist. 2 Heat losses associated with the infiltration of air through the cracks/openings are not considered. Analysis The rate of heat transfer through the window can be determined from ) ( window overall window out in T T A U Q = where T i and T o are the indoor and outdoor air temperatures, respectively, U overall is the U-factor (the overall heat transfer coefficient) of the
Background image of page 1
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: window, and A window is the window area. Substituting, Maximum heat loss: W 378 = = C )] 8 ( 20 )[ m 8 . 1 C)(1.2 W/m 25 . 6 ( 2 2 max window, Q & Q & Window 20 C -8 C Minimum heat loss: W 76 = = C )] 8 ( 20 )[ m 8 . 1 C)(1.2 W/m 25 . 1 ( 2 2 min window, Q & Discussion Note that the rate of heat loss through windows of identical size may differ by a factor of 5, depending on how the windows are constructed. 1-75...