Question: 512 Which of the following sterilization quality assurance measurements is designed to provide a written record of sterilizer cycle activity? A. Biological tests B. Bowie dick tests C. Mechanical recording charts/printouts Answer: C Question: 513 Some plastics including formulations of spun-bonded polyolefin are intended for use in ______ temperature sterilization processes. A. High B. Low Answer: B Question: 514 Paper-plastic pouches should NOT be labeled on the ______ side of the pouch. A. Paper B. Plastic Answer: A
Image of page 2
Question: 515 Tests which use live bacterial spores to challenge the efficacy of the sterilization process and provide a direct measure of lethality are called: A. Chemical indicator tests B. Biological tests C. Ampulization tests Answer: B Question: 516 When arranging instruments in an instrument tray, you should A. Position the instruments in a manner that will facilitate sterilization B. Arange the instruments in alphabetical order