Chapter 7 External Forced Convection 7-19E "!PROBLEM 7-19E" "GIVEN" T_air=60 "[F]" "x=10 [ft], parameter to be varied" Vel=7 "[ft/s]" "PROPERTIES" Fluid$='air' k=Conductivity(Fluid$, T=T_air) Pr=Prandtl(Fluid$, T=T_air) rho=Density(Fluid$, T=T_air, P=14.7) mu=Viscosity(Fluid$, T=T_air)*Convert(lbm/ft-h, lbm/ft-s) nu=mu/rho "ANALYSIS" Re_x=(Vel*x)/nu "Reynolds number is calculated to be smaller than the critical Re number. The flow is laminar." Nusselt_x=0.332*Re_x^0.5*Pr^(1/3) h_x=k/x*Nusselt_x
Background image of page 1
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: C_f_x=0.664/Re_x^0.5 x [ft] h x [Btu/h.ft 2 .F] C f,x 0.1 2.848 0.01 0.2 2.014 0.007071 0.3 1.644 0.005774 0.4 1.424 0.005 0.5 1.273 0.004472 0.6 1.163 0.004083 0.7 1.076 0.00378 0.8 1.007 0.003536 0.9 0.9492 0.003333 1 0.9005 0.003162 9.1 0.2985 0.001048 9.2 0.2969 0.001043 9.3 0.2953 0.001037 9.4 0.2937 0.001031 9.5 0.2922 0.001026 9.6 0.2906 0.001021 9.7 0.2891 0.001015 9.8 0.2877 0.00101 9.9 0.2862 0.001005 10 0.2848 0.001 7-8...