EE 330 Lecture 20 Bipolar Processes Bipolar Devices BJT JFET Thyristors SCR TRIAC
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Simple dc model V BE or I B Typical Output Characteristics 0 50 100 150 200 250 300 0 1 2 3 4 5 Vds Id I C V CE Forward Active Saturation Cutoff Forward Active region of BJT is analogous to Saturation region of MOSFET Saturation region of BJT is analogous to Triode region of MOSFET Review from Last Lecture
Background image of page 2
Simple BJT dc model Typical Output Characteristics Forward Active region of BJT is analogous to Saturation region of MOSFET Saturation region of BJT is analogous to Triode region of MOSFET I C V CE V BE or I B Saturation Forward Active Cutoff 0 0.5 1 1.5 2 2.5 3 0 1 2 3 4 5 VDS Cutoff Triode Saturation I D V DS V GS1 V GS2 V GS3 V GS4 Review from Last Lecture
Background image of page 3

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Simple dc model Simplified Multi-Region Model I C V CE V BE1 V BE2 V BE3 V BE4 V BE5 I C V CE V BE1 V BE2 V BE3 V BE4 V BE5 V CESAT Ebers-Moll Model Simplified Multi-Region Model 1 CE BE tt -V V VV CE R C S E R AF V 1+β I J A e e 1+ βV      AF CE V V E S C V V 1 e A J I t BE V BE =0.7V V CE =0.2V I C =I B =0 CE BE -V V B S E FR 11 I J A e - e ββ t V V E S B e β A J I Forward Active Saturation Cutoff Review from Last Lecture
Background image of page 4
Simple dc model Simplified Multi-Region Model AF CE V V E S C V V 1 e A J I t BE t V V E S B e β A J I q kT V t V BE =0.7V V CE =0.2V I C =I B =0 Forward Active Saturation Cutoff V BE >0.4V V BC <0 I C < β I B V BE <0 V BC <0 A small portion of the operating region is missed with this model but seldom operate in the missing region Review from Last Lecture
Background image of page 5

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Simple dc model Equivalent Simplified Multi-Region Model AF CE B C V V 1 βI I t BE V V E S B e β A J I q kT V t V BE =0.7V V CE =0.2V I C =I B =0 Forward Active Saturation Cutoff V BE >0.4V V BC <0 I C < β I B V BE <0 V BC <0 A small portion of the operating region is missed with this model but seldom operate in the missing region Review from Last Lecture
Background image of page 6
Simplified dc model Forward Active βI B I B B C E βI B I B B C E 0.6V Mathematically V BE =0.6V I C =βI B V BE =0.6V I C =βI B (1+V CE /V AF ) Or, if want to show slope in I C -V CE characteristics AF
Background image of page 7

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Image of page 8