p10 4. Plot dial gage readings R vs. log time for each load and fit a smooth curve for analysis. Calculate C v C a using the Casagrande construction: c V -.: R o Rso -_.J--"---a ____ :":::a 1 1 1 1 1 1 1 1 ---'--~---- --- 1 1 1 1 1 1 1 I - - _I- - -1- - - - "1- -:':-"-~~----b-.«:::. .: 1 1 1 time, t T5~ (~/,J) "l/{su -: O./~~ ( fI/l) 2/i~d (rJ: 1.. (7)1 Jo. ... t 1a Jf. ~"e.) C a = -Ae 1 (4/13) a) Find R o : choose t1, calculate 12 = t1/4, measure vertical distance "a" on from t1 to t2, R o is distance 2a above Rat t1 b) R 100 at "intersection" of primary secondary consolidation c) Find Rso by taking average of R o R d) Calculate C v as shown factor Tso e) Calculate C a : Calculate e for times hand 4 along secondary compression part 5. Plot dial reading R square root load. v using the alternate Taylor construction: R o Rgo \ \ t90 \ \ \ 1