MFET 243, Automated Manufacturing I 9/16/2009 Working with Universal Remote I/O 1 MFET 243 Fall ’09 Working with Working with Universal Remote I/O Topics Introduction to Universal Remote I/O The Pushbutton RediPANEL Introduction to the 1756-DH/RIO 2 Communications Module Configuring Universal Remote I/O with RSLogix 5000
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
MFET 243, Automated Manufacturing I 9/16/2009 Working with Universal Remote I/O 2 Introduction to Universal Remote I/O Introduction to Universal Remote I/O Universal remote I/O allows additional I/O to Universal remote I/O allows additional I/O to be connected to an Allen-Bradley PLC system Universal remote I/O is an older technology used extensively with PLC-5 systems 4 ControlLogix supports universal remote I/O in order to provide connectivity with legacy PLC-5 systems
Background image of page 2
MFET 243, Automated Manufacturing I 9/16/2009 Working with Universal Remote I/O 3 Universal Remote I/O Is: Proprietary to Rockwell Automation (Allen Proprietary to Rockwell Automation (Allen- Bradley) Based on serial communications 5 An example of a communications network A proven and reliable communications system Why use Universal Remote I/O? All the slots in the main processor chassis become All the slots in the main processor chassis become filled and you need more I/O In this case the remote chassis is generally located near the processor resident chassis (usually in the same control panel), OR 6 A group of I/O devices is located a long distance (e.g., 2000 feet) from the processor Instead of running many wires a long distance, a remote chassis can be placed next to the remote I/O devices
Background image of page 3

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
MFET 243, Automated Manufacturing I 9/16/2009 Working with Universal Remote I/O 4 Universal Remote I/O – Block Diagram Local Processor Resident Chassis ter supply Processor Power supply I/O Remote Chassis 7 Adap Power I/O To more remote I/O Scanner Adapter Remote I/O Link More Detailed Block Diagram Local Processor Remote I/O Local Processor Resident Chassis Remote Chassis 8 I/O To more remote I/O Scanner built into PLC-5 processor 1771-ASB
Background image of page 4
MFET 243, Automated Manufacturing I 9/16/2009 Working with Universal Remote I/O 5 The PLC-5 Universal Remote I/O Adapter Module The 1771- ASB Adapter module 9 PLC-5 Rack Sizes Remote I/O devices can be configured
Background image of page 5

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Image of page 6
This is the end of the preview. Sign up to access the rest of the document.

Page1 / 20

5 - Working wtih Universal RIO - Fall 09 - MFET 243,...

This preview shows document pages 1 - 6. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online