Mathcad - 05-18

Mathcad - 05-18 - V i 2390 V = V o 242 V = We are given the...

Info iconThis preview shows page 1. Sign up to view the full content.

View Full Document Right Arrow Icon
Since the voltage regulation is negative, we can conclude that the load has a leading power factor VR 1.24 - % = VR V nl V fl - V fl = Now we can solve for the voltage regulation: V nl 239V = V nl V i a = The no-load voltage will be the input voltage referred to the secondary side, which is done by dividing by the turns ratio: V fl 242V = V fl V o = The full load voltage is the output voltage, so
Background image of page 1
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: V i 2390 V = V o 242 V = We are given the output and the input voltage at full load: a 10 = a V prated V srated = First find the turns ratio Solution V srated 240 V = V prated 2400 V = S rated 500 MVA = Problem 5-18: MVA 1000 kW kVAR kW kVA kW...