Energy Losses in Bends and Fittings Apparatus

Energy Losses in Bends and Fittings Apparatus - facilitates...

Info iconThis preview shows page 1. Sign up to view the full content.

View Full Document Right Arrow Icon
Energy Losses in Bends and Fittings Apparatus. It consists of: - Sudden Enlargement - Sudden Contraction - Long Bend - Short Bend - Elbow Bend - Mitre Bend Apparatus: (Cont.) Flow rate through the circuit is controlled by a flow control valve. Pressure tappings in the circuit are connected to a twelve bank manometer, which incorporates an air inlet/outlet valve in the top manifold. An air bleed screw
Background image of page 1
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: facilitates connection to a hand pump. This enables the levels in the manometer bank to be adjusted to a convenient level to suit the system static pressure. A clamp which closes off the tappings to the mitre bend is introduced when experiments on the valve fitting are required. A differential pressure gauge gives a direct reading of losses through the gate valve....