Exercise 1 - GLP: Good laboratory practices - % error of mean= [(calculated avg vol.)-60mL]/60mL x 100% - p10, p200 (20-200 μL), p1000 (100-1000μL), upper 50% of their working range Volumes between 5 mL and 2 L are conveniently measured and transferred  with a graduated cylinder Volumes between 1 and 10 mL are conveniently measured and transferred  with a pipet - electronic balance: analytical balance- weighting chamber top-loading balance- .01 - mechanical balance: triple-beam balance is a mechanical balance that contains a pan attached to one side of  three parallel horizontal bars (beams) suspended on the balance. two-pan balance is a mechanical device that contains two pans supported symmetrically  on opposite sides of a pivot point. - Ex. 150mL of a 0.50 M solution: 342.3 g sucrose/mole x 0.50/L x L/1000mL x 150mL = 25.7g sucrose - C1xV1= C2V2  
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Exercise 2                                             17:04 - Abbe’s equation: d=0.612(wavelength)/(acceptance angle)A - field diaphragm- controls the position within the specimen plane that are illuminated - aperture diaphragm- controls the angles of light passing through the specimen plane,  thus affecting contrast and the resolution - Properties of microscope: magnification, resolution, contrast - By varying the curvature of the lens, we can produce different magnifications. -There are limits to magnification due to a phenomenon known as diffraction (bending of  light waves around small obstacles and the spreading out of waves past small openings) - The two most common ways to improve contrast in a microscope image are to change  how a) the specimen interacts with light, or b) the microscope interacts with the light that passes through the specimen - Kohler illumination:  focus on slide at 100x total magnification close field diaphragm center ball of light that appeared adjust the height of condenser until leaflets come into focus “ball of light” turns into  polygon with sharp edges  open field diaphragm - reticule is arbitrary unit of length, only useful if you have conversion factor for what  magnification you’re using  - we stained cheek cells with methylene blue, which binds to DNA, which is why we see  nucleus - parfocal-  lens  that stays in  focus  when  magnification / focal length  is changed. - elodea cells have stacks of chloroplast that move via cytoplasmic streaming. Slim mold  plasmodium use cytoplasmic streaming to move waste and nutrients at same time. It  can change flow direction as needed. Kalanchoe leaves have guard cells that surround  stomata
Background image of page 2
17:04 - Know how fluorescence works
Background image of page 3

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
Image of page 4
This is the end of the preview. Sign up to access the rest of the document.

Page1 / 13

Midterm Review - Exercise1 GLP:Goodlaboratorypractices

This preview shows document pages 1 - 4. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online